Private Wells and Septic Systems

No city water, no city sewer — the job is yours

Public water systems get tested by the utility. A private well is monitored by no public agency — its safety is the owner's responsibility, as EPA states. After a flood, assume both your well and your septic system are compromised until each has been checked.

The well: do not drink it yet

EPA's guidance for flooded wells is direct: do not use water from a flooded well for any purpose until you have talked with proper health authorities. Do not turn on the pump and do not flush the well — running a contaminated or damaged pump can spread contamination and damage equipment, and submerged wiring is an electrical hazard. Have the pump and wiring checked first.

The safe sequence:

  1. Use bottled water, or water boiled for at least one minute or disinfected with bleach, for drinking, cooking, and brushing teeth.
  2. Contact your local or county health department for testing instructions.
  3. Have the well disinfected — EPA directs owners to have the well disinfected by a well contractor in its flood guidance — and then have the water sampled and tested to confirm it is safe. Water that looks and smells fine can still carry bacteria.
  4. Keep testing over time. EPA cautions that a well may not be a safe source for months after a flood, even after one safe test, because floodwater and failing septic systems can keep contaminating groundwater. EPA guidance commonly used by health departments is to test for bacteria about 7 to 10 days after disinfection, and to retest after heavy rain.

If the water smells like gasoline or chemicals, tell the health department — disinfection does not fix chemical contamination.

The septic system: use less, pump later

EPA's septic guidance surprises people: do not pump the tank while the drainfield is flooded or the ground is saturated. An emptied tank in saturated ground can try to float out of the ground and damage its inlet and outlet pipes — and pumping is at best a temporary fix while the field is under water.

Instead:

The traps